Altivar 312 - Botek Otomasyon Default is AI1 (0-10VDC) Other options are AI2, AI3, A1U1, UPdt, UPdh, LCC, Ndb or n Et or Fr2= Sets where the secondary speed reference comes from. Schneider Electric for any consequences arising out of the use of this product. © 2009 Schneider. This manual is a simplified version of the User manual.

Altivar 312 Programming Manual, BBV46385 - Schneider Resolution: dr C Menu Parameter setting Description b Fr Standard Motor frequency (50Hz or 60Hz depending on the motor and power system) Un S Rated Motor Voltage Fr S Rated Motor Frequency (usually matches b Fr) n Cr Rated Motor Current (nameplate current for the motor at the voltage it's being used) n SP Rated Motor Speed (nameplate RPM for the motor at the frequency it's being used) t Fr Max Frequency u Ft Motor control type (defaults to n; Sensorless Vector Control, some applications work better at L; Standard V/Hz) SET Menu ACC Acceleration d EC Deceleration LSP Low Speed HSP Hh Speed It H Motor Thermal (set to the motor nameplate current for the voltage being used, provides Overload protection) u Fr Voltage boost (usually can be left at default) CLI Current limitation (sets peak current allowed to go to the motor. Altivar 312 Programming Manual, BBV46385. This manual details how to program the ATV312 drive using the built-in user interface or remote keypad. It shows.

ATV312 Basic programming - Schneider If set too low, can prevent the motor from reaching the commanded speed; display will flash off and on) IO Menu t CC 2/3 wire type (default is 2C; 2 wire control) t Ct 2 wire type (default is trn; drive must see the transition (off to on) of the run command to start the motor.) Some applications require this to be changed to LEL. rr S Reverse assn (default is LI2) WHEN in 2C (2 wire control) LI1 is the Run Forward input. ATV312 Settings that should be changed or at least reviewed when setting. Refer to the ATV312 Programming manual BBV46385 for additional information.

SoMove Setup software - Eurotherm When in 3C (3 wire control) LI1 is a Stop input, LI2 is Run Forward and LI3 is Run Reverse. Schneider Electric provides you with the complete set of industrial automation. b ATV 12, ATV 312, ATV 31, ATV 32, ATV 61, ATV 71 and Altivar Process drives. v display and debug the program already on the drive.

ATV312 Manual de instalación - Eurotherm Ct L menu LAC= L1, L2 or L3 (default is L1, L2 and L3 enable advanced functions in the drive) Fr1= Sets where the speed reference comes from. Ni Schneider Electric ni ninguna de sus filiales o asociados asumirán. Lea detenidamente este manual antes de instalar o manipular el variador Altivar 312.